Kubota BX1500, BX1830, BX2230, BX23 Air Cleaner Element
BX1500 / BX1830 / BX2230 / BX23 Owner Service Guide
The air cleaner uses a single dry paper element. Clean it every 100 hours and replace it once a year or after every sixth cleaning, whichever comes first. In dusty conditions, clean it more often than the 100-hour interval. A clogged element reduces engine power and causes black exhaust smoke.
| Interval | Clean every 100 hours. Replace every year or after 6 cleanings. Open the evacuator valve weekly, or daily in dusty conditions. |
|---|---|
| Time | 15 minutes |
| Tools | Compressed air with a regulator, flashlight |
| Parts | Air cleaner element (for replacement) |
Air cleaner layout
Open the hood to reach the air cleaner. The BX1500, BX1830, BX2230 and BX23 all use the same round housing and element. The cover twists off and carries the rubber evacuator valve on its underside. The cover is marked TOP.
Evacuator valve
The evacuator valve is a rubber duckbill on the bottom of the cover. Squeeze it open once a week under normal use, or daily when working in dust, to let large dirt particles fall out of the housing. Check that the valve is not blocked with dust. A torn or missing valve lets dust build up in the housing; replace it.
Cleaning the element
- Park on level ground, set the parking brake, stop the engine and remove the key. Open the hood.
- Remove the air cleaner cover and pull the element straight out of the housing.
- Wipe the inside of the housing and the cover with a clean, dry rag. Do not let dirt fall into the open outlet of the housing.
- If the element is covered with dry dust, blow compressed air through it from the inside out while turning the element. Keep the air pressure below 30 psi and hold the nozzle a few inches from the paper. Higher pressure or a nozzle against the paper will tear the media.
- If the element has carbon or oil on it, soak it in a mild detergent solution for 15 minutes, wash it several times in water, rinse it with clean water, and let it air dry completely. Do not use heat or compressed air to dry it.
- Shine a flashlight inside the element and look through the paper. Replace the element if you see pinholes, tears, or light coming through unevenly, or if the gasket at the end is cracked or flattened.
- Install the element and push it fully into the housing.
- Install the cover with the arrow marks aligned and the TOP mark up. If the cover is not aligned, incoming air bypasses the baffle and loads the element with dust, and the evacuator valve will not work.
The air cleaner uses a dry element. Never oil it.
Replacing the element
Replace the element once a year or after the sixth cleaning, whichever comes first, even if it looks clean. Also replace it any time it is damaged or will not clean up. Remove and install the element using the same steps as cleaning.
The same element, K1211-82320, fits all four models. The BX filter maintenance kit for the BX1500, BX1830 and BX2230 includes the air cleaner element, both fuel filters and the oil filter cartridges.
These tractors use a single element with no inner safety element. For more on safety elements on Kubota engines, see our video:
Intake hose and clamps
While the hood is open, check the intake hose between the air cleaner and the engine. The hose must be free of cracks and the clamps must be tight. A leak downstream of the element lets unfiltered air into the engine. See hose and line inspection.
Parts
| Part | Part number | Notes |
|---|---|---|
| Air cleaner element | K1211-82320 | All four models |
| BX filter maintenance kit | 77700-03362 | BX1500, BX1830, BX2230. Includes the air cleaner element. |
| Evacuator valve | K1211-82340 | |
| Air cleaner cover | K1211-82330 | |
| Cover clip | K1211-82350 | 2 per tractor |
Related
- Hose and line inspection
- Fuel filter replacement
- Coolant change and flush
- BX1500 / BX1830 / BX2230 / BX23 Owner Service Guide