Kubota BX1500, BX1830, BX2230, BX23 Battery Check
BX1500 / BX1830 / BX2230 / BX23 Owner Service Guide
Check the battery every 100 hours. If the tractor runs less than 100 hours a year, check it once a year. The factory battery is a maintenance-free type, but it still loses charge in storage, and loose or corroded terminals will keep the engine from cranking even when the battery itself is good. A weak battery shows up as slow cranking and dim lights.
| Interval | Every 100 hours, or once a year if used less than 100 hours a year |
|---|---|
| Time | 15 minutes, plus charging time if needed |
| Tools | Digital voltmeter, terminal brush, wrenches, safety glasses, rubber gloves |
| Supplies | Multipurpose grease for the terminal posts |
Battery specification
When the battery is replaced, use one with the same rating. The BX1500 and BX1830 use the smaller battery.
| Model | Battery type | Voltage | Cold cranking amps | Reserve capacity |
|---|---|---|---|---|
| BX1500, BX1830 | 26/26R | 12 V | 435 | 62 minutes |
| BX1830 (alternate) | 65D23L | 12 V | 490 | 111 minutes |
| BX2230, BX23 | 526RA | 12 V | 535 | 80 minutes |
| BX2230 (alternate) | 75D23L | 12 V | 550 | 90 minutes |
Getting to the battery
Park on level ground, set the parking brake, stop the engine and remove the key. The battery sits in the compartment under the instrument panel, ahead of the seat. The side panel is held by a knob; remove it to reach the battery. If dust or chaff has built up in the battery compartment, clean it out before going further; debris around the battery and wiring is a fire hazard. Reinstall the panel fully on the center pillar when finished so dust stays out.
Checking the state of charge
Indicator (65D23L and 75D23L batteries)
| Indicator | Condition |
|---|---|
| Green | Charge and electrolyte are both good |
| Black | Battery needs charging |
| White | Battery needs replacing. Do not charge it. |
Voltmeter
With the key off, put the voltmeter's negative lead on the negative post and the positive lead on the positive post. Read the voltage and compare it to the table. A battery reading below 12.6 V is not fully charged. If the reading is low, charge the battery before putting the tractor back to work.
| Battery voltage | State of charge |
|---|---|
| 12.6 V | 100 % |
| 12.4 V | 75 % |
| 12.2 V | 50 % |
| 12.0 V | 25 % |
| 11.8 V | 0 % |
Refillable batteries
If the tractor has a refillable battery with removable caps, check the electrolyte level in each cell. It must be between the upper and lower level marks, which is the bottom of the vent well. Add distilled water as needed in a well-ventilated area. Do not charge or use a refillable battery with the electrolyte below the lower mark. Never remove the caps while the engine is running.
Cables and terminals
Inspect both cables for chafed or cracked insulation, and check the clamps for looseness, corrosion, or discoloration from heat.
- Remove the negative (−) cable, then the positive (+) cable.
- Clean the posts and the inside of the clamps with a terminal brush until they are bright metal.
- Reinstall the positive (+) cable first, then the negative (−) cable. Tighten both clamps firmly.
- Apply a moderate amount of grease to the terminals. The terminals are on the 50-hour grease points list for this reason.
Removing and installing the battery
- Remove the side panel under the instrument panel.
- Disconnect the negative (−) cable, then the positive (+) cable.
- Remove the nuts from the two hold-down rods and lift off the battery holder.
- Lift the battery out.
- To install, set the battery in place, fit the holder and rods, and tighten the nuts snug.
- Connect the positive (+) cable first, then the negative (−) cable.
- Reinstall the side panel.
Charging
- For a normal slow charge, connect the charger positive to the battery positive and the charger negative to the battery negative, and charge in the standard way.
- A boost charge is for emergencies only. It puts in a partial charge at a high rate. Recharge a boost-charged battery normally as soon as possible, or its service life will be shortened.
- On a refillable battery, charging is complete when the electrolyte reads between 1.27 and 1.29 specific gravity.
Storing the tractor
For long-term storage, remove the battery and store it in a dry place out of direct sunlight. A battery discharges on its own in storage, so recharge it every 3 months in hot weather and every 6 months in cold weather. For more on preparing the battery for winter, see our video:
Jump starting
- Bring the helper vehicle within cable reach. The two machines must not touch.
- Set the parking brake on both, put the shift levers in neutral, and shut both engines off.
- Put on safety glasses and rubber gloves.
- Make sure any vent caps are tight and cover the vent holes with a damp rag. Keep the rag off the terminals.
- Connect the red cable to the positive (+) post of the dead battery, then the other end to the positive (+) post of the helper battery.
- Connect the black cable to the negative (−) post of the helper battery.
- Connect the other end of the black cable to the engine block or frame of the tractor, as far from the dead battery as possible.
- Start the helper vehicle and let it run a few moments, then start the tractor.
- Remove the cables in the reverse order: engine or frame ground, helper negative, then both positive ends. Discard the damp rag.
Troubleshooting
| Symptom | Cause | Remedy |
|---|---|---|
| No electrical equipment operates | Battery discharged, a cable loose, or the 30 A slow-blow fuse blown | Charge the battery, tighten the cables, or replace the slow-blow fuse. See Fuse replacement. |
| Starter does not turn, battery charged | Poor terminal connection | Clean and tighten the terminals. |
| Battery will not take a charge, or indicator is white | Battery worn out | Replace the battery. |
| Battery runs down quickly | Fan belt slipping, or a charging system fault | Adjust or replace the fan belt. If the belt is good, have the charging system checked. |
Parts
| Part | Part number | Notes |
|---|---|---|
| Battery cable, positive (+) | K2561-61310 | All models |
| Battery cable, negative (−) | K2561-61350 | All models |
| Battery cable 2, negative (−) | K1211-61360 | All models |
| Battery holder | K2561-61120 | Hold-down |
| Battery rod | K2561-61130 | 2 per tractor |
| Flange nut | 02751-50060 | Hold-down rods, 2 per tractor |
Related
- Grease points
- Engine start system check
- Fuse replacement
- Fan belt adjustment
- BX1500 / BX1830 / BX2230 / BX23 Owner Service Guide
To have the battery tested or replaced at Messick's, schedule service.